Grupo EMINSA
R
RSTby EMINSA

ETRYS Transformers

Units restored under world-class standards. Immediate availability, competitive costs, and 18-month warranty.

Speed

Fast Delivery

Savings

Up to 40%

Reliability

Certified

Environmental Impact

Eco-Friendly

Remanufactured Pole-Type Transformers
ETRYS by EMINSA
ANSIIEEE C57
Remanufactured Transformer

Remanufactured Pole-Type Transformers

ETRYS by EMINSA pole-type transformers offer a reliable and cost-effective solution for overhead distribution.

Power

15 – 500 kVA

Voltage

Up to 34.5 kV

Main features:

Certified comprehensive restoration
Complete electrical testing
Structural refurbishment
New critical components
18-month warrantyIndustry leader
Remanufactured Pad-Mounted Transformers
ETRYS by EMINSA
ANSIIEEE C57
Remanufactured Transformer

Remanufactured Pad-Mounted Transformers

ETRYS by EMINSA pad-mounted transformers are safe and efficient for underground distribution.

Power

30 – 3,000 kVA

Voltage

Up to 34.5 kV

Main features:

Sealed and hermetic design
Protection against accidental contacts
Weather resistant
Low energy losses
18-month warrantyIndustry leader
Remanufactured Substation Transformers
ETRYS by EMINSA
ANSIIEEE C57
Remanufactured Transformer

Remanufactured Substation Transformers

ETRYS by EMINSA substation transformers provide high performance for demanding applications.

Power

Up to 3,000 kVA

Voltage

Up to 34.5 kV

Main features:

Reinforced structural refurbishment
Rigorous insulation testing
Custom configurations
Tap changers
18-month warrantyIndustry leader

Quick Comparison

FeaturePole-TypePad-MountedSubstation
Power15 – 500 kVA30 – 3,000 kVAUp to 3,000 kVA
VoltageUp to 34.5 kVUp to 34.5 kVUp to 34.5 kV
Standards
ANSIIEEE C57
ANSIIEEE C57
ANSIIEEE C57
Warranty18 months18 months18 months
Quality Control

Tests Performed

Every remanufactured transformer goes through a rigorous testing program to ensure its performance and safety.

Megger

Measures insulation resistance.

TTR

Verifies transformation ratio.

Resistance

Measures ohmic resistance of windings.

Losses

Determines energy losses.

Excitation

Evaluates magnetic core condition.

Impedance

Measures short-circuit impedance.

DGA

Optional

Detects dissolved gases in oil.

PCB

Analyzes oil for polychlorinated biphenyls.

Power Factor

Optional

Evaluates insulation quality.

Can't find what you're looking for?

We manufacture and remanufacture custom transformers to your specifications. Contact us for a personalized solution.

Request Custom Quote